Gas plant room with a line of pressure vessels, yellow service pipework and process skids

Standards & specifications

The standards our gas and plant are made to

Which Indian Standard applies to your gas, your cylinder, its valve, its colour, its filling and its next hydrostatic test — and, for each one, how KIGL conforms to it. Written by a manufacturer that has made gas since 1947 and sat on the BIS committees behind these standards.

7
Standards explained
10
We manufacture and test to
BIS
Committee members
Standard Subject What it governs Read
IS 308 · IS 7312:2018 The standards for dissolved acetylene IS 308, IS 7312, IS 8433, IS 16271 and IS 11006 explained — the specification, cylinder, testing and filling standa… Read
IS 309 · IS 7285 (Part 1):2018 The standards for industrial oxygen IS 309, IS 7285, IS 3224, IS 15975 and IS 8451 explained — the gas, cylinder, valve, filling and retest standards t… Read
IS 4379:1981 · IS 3933 IS 4379 gas cylinder colour codes in India, gas by gas The IS 4379 ground colours and neck bands for every industrial gas cylinder in India, why oxygen and carbon dioxide… Read
IS 8451:2018 · IS 8433:2017 Gas cylinder retest intervals How often a gas cylinder must be retested in India, which standard applies to which gas, what requalification invol… Read
IS 8471:2003 · IS 14814:2023 The Indian Standard for acetylene generators What IS 8471:2003 covers, why acetylene generators need a standard of their own, and how it works with the IS 14814… Read
Indian Pharmacopoeia · IS 3745:2024 Medical gas standards in India: IP, IS 3745 pin-index and IS 3933 Why medical oxygen is a drug and not an industrial gas — the Indian Pharmacopoeia monograph, the IS 3745 pin-index… Read
IS 11006:2011 · IS 16485:2020 Flashback arrestor standards IS 11006, IS 16485 and EN ISO 5175-1 explained — what a flashback arrestor must do, where it must be fitted, and wh… Read

The standards KIGL works to

Every gas we fill, every cylinder it goes into and every piece of equipment we build is made to a named Indian Standard. These are ours, with the edition, so they can be checked rather than taken on trust.

What we do Standard How we conform
The gas we fill Each gas is filled to its own Indian Standard specification, not to a general one.
Dissolved acetylene Guwahati works IS 308:1988 Dissolved Acetylene (Gas) Filled to the IS 308 specification in cylinders to IS 7312.
Industrial oxygen Guwahati works IS 309:2023 Oxygen, Compressed Gas and Liquid — Specification Filled to the IS 309 specification.
Nitrogen Guwahati works IS 1747:2023 Nitrogen, Compressed Gas and Liquid — Specification (Second Revision) Filled to the IS 1747 specification.
Carbon dioxide Guwahati works IS 307:1966 Carbon Dioxide Filled to the IS 307 specification.
Argon Guwahati works IS 5760 Argon, Compressed and Liquid Filled to the IS 5760 specification.
Hydrogen IS 1090:2002 Compressed Hydrogen Supplied to the IS 1090 specification.
The cylinders it goes into Construction, identification and the periodic test that keeps a cylinder in service.
Cylinder periodic testing Guwahati works IS 8451:2018IS 8433:2017 Periodic Inspection and Testing of Seamless Steel Gas Cylinders; Periodic Inspection and Maintenance of Dissolved Acetylene Gas Cylinders Cylinders are hydrostatically retested and requalified on the statutory cycle — IS 8451 for seamless steel, IS 8433 for dissolved acetylene.
Cylinder identification and colour Guwahati works IS 4379:1981IS 3933 Identification of the Contents of Industrial Gas Cylinders; Medical gas cylinder colours Cylinders are painted, banded and marked to IS 4379; medical cylinders follow IS 3933.
The equipment we build Plant and safety equipment manufactured at the Kolkata works.
Acetylene generating plant Kolkata works IS 8471:2003IS 14814:2023 Acetylene Generators — Requirements; Acetylene — Code of Safety Plants are designed and manufactured to IS 8471 and laid out to the IS 14814 code of safety.
Flashback and flame arrestors Kolkata works IS 11006:2011 Flame Arrestor for Use with Fuel Gases Manufactured to the IS 11006 requirements. No third-party type-test certification is claimed.