Guide

How oxygen is made: cryogenic air separation PSA, and how the gas gets into a cylinder to IS 309

Oxygen is made from air, which is 20.95 % oxygen. Large plants compress, clean and cool air until it liquefies, then distil it: nitrogen boils off at −195.8 °C and oxygen collects as liquid at −183 °C. Smaller plants use PSA, where a zeolite holds back nitrogen and gives 90 to 96 % oxygen.

Gas plant piping and valves at a KIGL works
Oxygen in dry air
20.948 % by volume; nitrogen 78.084 %
Boiling points that make distillation work
Nitrogen −195.8 °C
First air separation patents
Linde air liquefaction DRP 88
PSA purity ceiling
About 95.7 % if all nitrogen is removed
Industrial oxygen grades
IS 309:2023 Grade 1

Oxygen is made from air. There is no mine and no feedstock to buy: what a producer pays for is the electricity to separate the 20.95 % of air that is oxygen from everything else. There are two industrial ways to do it. Cryogenic air separation liquefies and distils air, and is how almost all liquid oxygen and the purest gaseous oxygen are made. Pressure swing adsorption (PSA) uses a zeolite to hold back nitrogen at room temperature, and is how most on-site plants work. This page walks through both, then follows the gas into a cylinder and through IS 309:2023 testing.

What is air made of?

Component Share of dry air, by volume Boiling point at 1 atm Fate in an air separation unit
Nitrogen, N₂ 78.084 % −195.8 °C Product, or vented as waste gas
Oxygen, O₂ 20.948 % −182.96 °C Product
Argon, Ar 0.934 % −185.85 °C Recovered in a side column at larger plants
Carbon dioxide, CO₂ about 0.04 % (about 420 ppm) sublimes at −78.5 °C Removed before cooling, or it freezes
Neon, Ne 18.18 ppm −246.05 °C Recovered at a few large plants
Helium, He 5.24 ppm −268.93 °C Not recovered from air in practice
Krypton, Kr 1.14 ppm −153.42 °C Concentrates in the oxygen; recovered at a few plants
Xenon, Xe 0.087 ppm −108.10 °C Concentrates in the oxygen; recovered at a few plants
Water vapour variable, up to a few % 100 °C Removed before cooling, or it freezes

Composition: US Standard Atmosphere 1976; carbon dioxide from the NOAA Global Monitoring Laboratory. Boiling points: NIST Chemistry WebBook.

The three columns that matter are nitrogen, argon and oxygen. Their boiling points lie within 13 K of each other, nitrogen lowest, then argon, then oxygen. That small spread is what a distillation column works with, and it is why argon, sitting only 2.9 K below oxygen, is the hardest of the three to separate.

How oxygen is made by cryogenic air separation

The process dates from the turn of the twentieth century. Carl von Linde patented air liquefaction in 1895 (DRP 88,824) and a rectification process for separating oxygen in 1902 (BP 1740 of 1902); Georges Claude patented an expansion engine for the refrigeration in 1903 (BP 16,208). Modern plants are much larger and far more efficient, but the sequence is the same.

  1. Filter and compress. Air is drawn through an intake filter and compressed in stages, with cooling between stages. The intake location matters: hydrocarbons drawn in will end up in the liquid oxygen.
  2. Purify the front end. Water vapour and carbon dioxide would freeze solid and block the cold equipment, so they are removed first, today usually in switching beds of molecular sieve. The same beds take out most hydrocarbons, including acetylene.
  3. Cool against the products. The clean air passes through a main heat exchanger, cooled by the cold product and waste streams leaving the plant, and is cooled until it is close to liquefying.
  4. Make the refrigeration. Part of the air is expanded through a turbine, doing work and cooling sharply. This is Claude's principle; Linde's original machines used expansion through a valve. The turbine makes up for heat leaking into the cold box.
  5. Distil. Air enters a double column. In the higher-pressure lower column it separates into nitrogen at the top and an oxygen-rich liquid at the bottom. That liquid feeds the low-pressure upper column, where nitrogen leaves from the top and nearly pure oxygen collects at the bottom. A condenser-reboiler links the two: nitrogen condensing on one side boils oxygen on the other.
  6. Recover argon. At larger plants, an argon-rich stream is drawn from the middle of the upper column into a side column and refined. Argon is not separated by PSA in practice.
  7. Deliver. Oxygen leaves either as gas, warmed in the main exchanger and sent to a pipeline, or as liquid drawn into vacuum-insulated storage for tankers. Making liquid costs extra refrigeration, so plants that sell mainly liquid have a liquefier.

The danger point in this sequence is the liquid oxygen sump at the bottom of the upper column. Anything less volatile than oxygen collects there, including hydrocarbons that slip past the front end. Acetylene is the most dangerous, because it is barely soluble in liquid oxygen and can come out as solid. PESO's layout rules for acetylene plants respond directly: at least 30 m to oxygen plants and 90 m to air compressor intakes. The full layout table is on acetylene plant layout and safety distances.

Pressure swing adsorption: the PSA zeolite cycle

A PSA oxygen plant does at room temperature what the column does at cryogenic temperature, by a different mechanism. Compressed, dried and filtered air flows through a bed of zeolite molecular sieve, which adsorbs nitrogen more strongly than oxygen. Oxygen-rich gas passes through. When the bed approaches saturation, the feed switches to a second bed and the first is depressurised, releasing its nitrogen to atmosphere. The two beds alternate continuously.

The zeolite cannot separate argon from oxygen, so argon travels with the product. If every molecule of nitrogen were removed, the product would be 20.948 parts of oxygen to 0.934 of argon, or about 95.7 % oxygen. Real plants run slightly below that ceiling. The WHO International Pharmacopoeia (11th edition, 2022) covers PSA oxygen as Oxygen 93, with an allowed range of 90 to 96 % (93 ± 3 %), as summarised in a Global Fund briefing note of April 2024. The detail of the cycle, feed air quality and running cost is on how PSA oxygen generation works, and the choice between the two technologies is on PSA vs air separation.

From plant to cylinder

Cylinder oxygen is filled in one of two ways. A filling station supplied with liquid oxygen uses a cryogenic pump to raise the liquid to cylinder pressure and an ambient vaporiser to warm it, which avoids compressing gas and gives a very dry product. A station supplied with gas uses an oxygen-service compressor. Either way the gas reaches a filling manifold and the cylinders on it, typically to about 150 bar at 15 °C. A 46.7 litre cylinder at that pressure holds about 10.1 kg of oxygen (NIST density 215.6 kg/m³ at 150 bar and 15 °C), which is about 7.4 m³ at 15 °C and 1 atm, or about 7.7 m³ on the IS 309 basis of 27 °C and 760 mm Hg.

Filling and the cylinders themselves fall under the Gas Cylinders Rules 2016, and the cylinders are periodically examined and hydrostatically tested; see cylinder testing and retest. Industrial oxygen cylinders are Graphite Black, RAL 9011, throughout under IS 4379:2021. Medical cylinders follow IS 3933:2021, with a white shoulder.

Rules that matter

IS 309:2023 is the Indian specification for industrial oxygen, compressed and liquid. It sets three grades:

Characteristic Grade 1 (N3.5) Grade 2 (N2.5) Grade 3 (N2.0)
Oxygen, % v/v, min 99.95 99.5 99.0
Nitrogen, ppm, max 100.0 100.0 —
Water vapour, ppm, max 1.5 2.0 67
Carbon dioxide, ppm, max 0.2 0.5 2.0
Carbon monoxide, ppm, max 0.2 0.5 3.0
Hydrocarbons, ppm, max 10.0 20.0 50.0

Three clauses describe how the product is checked:

IS 309:2023 testing of the product

  • Sampling by lot (Annex C) A lot is every cylinder charged at one time from one manifold. Five cylinders are taken from a lot of up to 50, eight from 51 to 100, fifteen from 101 to 150, twenty from 151 to 300 and twenty-five from 301 or more. The lot passes only if every sample passes.
  • Air-separation product (Table 1, Note 1) Oxygen made by air separation should not normally contain carbon monoxide, carbon dioxide or hydrocarbons, so those three are tested only by agreement between buyer and seller. Oxygen made by other routes is tested for them routinely.
  • Referee method (Note 2) For Grades 2 and 3 either assay method may be used, but method A-1 is the referee in any dispute.

Medical oxygen is outside IS 309 altogether: clause 1 excludes oxygen for medical or inhalation purposes, which is governed by the Indian Pharmacopoeia. The full data sheet is on oxygen technical data.

Where KIGL fits

KIGL fills industrial oxygen to IS 309:2023 Grade 2 (N2.5), minimum 99.5 %, and medical oxygen, at its own PESO-approved works at Noonmati, Guwahati, and Howrah, Kolkata. KIGL also operates an air separation plant and supplies liquid oxygen. KIGL builds PSA oxygen plants for sites that want to make their own. Cylinder supply is on the oxygen page.

How oxygen is made — frequently asked questions

How is oxygen manufactured industrially?

Almost all of it comes from air. Large tonnage plants use cryogenic air separation: air is compressed, stripped of water and carbon dioxide, cooled until it liquefies and distilled in a column, which gives oxygen up to 99.5 % or purer as gas or liquid. Smaller on-site plants use pressure swing adsorption over zeolite, giving 90 to 96 %. Water electrolysis also makes oxygen, but as a by-product of hydrogen.

How is oxygen separated from air?

By exploiting differences in boiling point or in adsorption. In distillation, liquid air is boiled in a column: nitrogen, boiling at −195.8 °C, rises to the top, while oxygen, boiling at −182.96 °C, collects at the bottom. In PSA, a zeolite adsorbs nitrogen more strongly than oxygen at pressure, so oxygen-rich gas passes through and the bed is cleared by dropping the pressure.

What percentage of air is oxygen?

20.948 % by volume in dry air, from the US Standard Atmosphere 1976 composition, usually rounded to 21 %. Nitrogen is 78.084 %, argon 0.934 % and carbon dioxide about 0.04 %. By mass oxygen is about 23 % of dry air, because the O₂ molecule is heavier than N₂. Water vapour varies from almost nothing to a few per cent and is removed before separation.

When was oxygen first produced from air?

Carl von Linde patented a process for liquefying air in 1895 (German patent DRP 88,824) and a rectification process for separating oxygen from liquid air in 1902 (British patent 1740 of 1902). Georges Claude added an expansion engine for refrigeration (British patent 16,208 of 1903). Before that, oxygen was made chemically, which is why it was costly and scarce.

How is oxygen filled into cylinders?

Either liquid oxygen is pumped to high pressure by a cryogenic pump and warmed in a vaporiser, or gas is compressed by an oxygen-service compressor. The gas goes to a filling manifold and into cylinders, typically to about 150 bar at 15 °C. Each lot filled from one manifold is sampled under IS 309:2023, and contents are declared in cubic metres at 27 °C and 760 mm Hg.

Why must acetylene be kept away from an oxygen plant's air intake?

Because hydrocarbons drawn into an air separation unit concentrate in the liquid oxygen at the bottom of the column, and acetylene is the most dangerous of them. PESO's layout rules therefore keep an acetylene plant at least 30 m from oxygen plants and 90 m from air compressor intakes, the 90 m figure being stricter than the equivalent European guidance.

References

  1. Bureau of Indian Standards. (2023). Oxygen, compressed gas and liquid — Specification (IS 309:2023, Fifth Revision).
  2. Linstrom, P. J., & Mallard, W. G. (Eds.). (n.d.). NIST Chemistry WebBook (NIST Standard Reference Database 69). National Institute of Standards and Technology. [normal boiling points of nitrogen, argon and oxygen] https://webbook.nist.gov/chemistry/
  3. NOAA Global Monitoring Laboratory — atmospheric carbon dioxide
  4. PESO Gas Cylinders Rules SOP — acetylene plant safety distances
  5. The Global Fund, PSA Plant Oxygen Purity briefing note, April 2024 (citing the WHO International Pharmacopoeia, 11th edition, 2022)
  6. US Standard Atmosphere 1976, NOAA/NASA/USAF — composition of dry air

Enquiries

Request a quotation

State the gas or equipment, the quantity or capacity, and your location. KIGL will confirm the grade, the cylinder or plant size, and whether the location can be served from Noonmati, or through the agent network.