Guide
Acetylene cylinder sizes in India: why they are measured in litres of water not cubic metres of gas
Indian dissolved acetylene cylinders are specified by water capacity, not gas volume. The two common sizes are about 17 litres, holding roughly 3.2 kg of acetylene, and 41 litres, holding about 7 kg. Tare weights are 29 and 55 kg, because the porous mass and acetone are part of the cylinder.
- How a size is stated
- Water capacity in litres
- Common Indian sizes
- About 17 litres
- Why the tare is so high
- 29 kg empty for a 17 litre cylinder
- Gas to volume conversion
- 1 kg of acetylene ≈ 0.91 m³
- Maximum settled pressure
- 16 kgf/cm² at 15 °C
On this page 8 sections
The question behind the question #
"What size acetylene cylinder is supplied?" is almost always asked in the wrong units. People ask for cubic metres, because that is how gas is bought. Cylinders are made and regulated in litres of water capacity, and the two numbers are not proportional.
That is not pedantry. In an oxygen cylinder the shell is empty and the gas volume follows from the water capacity and the pressure. A dissolved acetylene cylinder is full before any gas goes in: a monolithic porous mass fills it, the mass is soaked in acetone, and the acetylene is dissolved into the acetone. How much gas a given shell holds therefore depends on the porous mass, the acetone charge and the filling pressure — not on the shell alone.
So the water capacity is the honest specification, and every standard is written against it.
The two sizes that cover Indian industrial use #
| Smaller | Larger | Larger, seamless | |
|---|---|---|---|
| Water capacity | 17.2 litres | 41 litres | 41 litres |
| Nominal gas content | ≈3.2 kg | ≈7 kg | ≈7 kg |
| Outside diameter | 185 mm | 258 mm | 232 mm |
| Length without valve | 815 mm | 960 mm | 1,220 mm |
| Wall thickness | 4 mm | 4 mm | 5.6 mm |
| Tare weight | 29 kg | 55 kg | 65 kg |
| Shell type | Three-piece welded | Three-piece welded | Seamless |
| Fusible plugs | Two | Two | None |
These are the Indian market standard, taken from a BIS-certified cylinder manufacturer's published specification against IS 7312:1993, with valves to IS 3224. They are not presented as KIGL's own fleet, and no KIGL-specific size is claimed on this page; which sizes KIGL stocks is an open question recorded in the verify note.
The 7 kg cylinder is the one most Indian fabrication shops mean when they say "a DA cylinder".
Why an empty cylinder weighs 29 or 55 kg #
Because it is not empty. Of that tare, only a part is steel:
- The porous mass is a monolithic calcium silicate, 90–92 % porous, with a minimum crushing strength of 22 kgf/cm² — the exact minimum of IS 7312:1993 cl 19.2.4. It is cast in place and never removed.
- The acetone occupies around 43 % of the water capacity by volume for cylinders above 9 litres, under IS 7312:1993 cl 19.3.2.
Both stay in the cylinder for its whole life, which is why the stamped tare includes everything except the deliverable gas, and why contents are a weight and never a pressure.
Converting to the units of purchase #
One kilogram of acetylene is about 0.91 m³ — 0.90 at 15 °C and 0.92 at 20 °C, from the densities compiled by Miller from Bottomley, Reeves and Seitlow. So:
- a 3.2 kg cylinder is roughly 2.9 m³
- a 7 kg cylinder is roughly 6.4 m³
Use the nominal figure for planning and the weighbridge for anything that matters. The actual content of any given cylinder is its gross weight minus the stamped tare, and the arithmetic is on checking contents by weight.
Where size changes the rules, and where it does not #
Pressure does not change with size. Every dissolved acetylene cylinder is limited to 16 kgf/cm² settled at 15 °C under Rule 37(vi) of the Gas Cylinders Rules 2016, whether it holds 3.2 kg or 7 kg.
Three things do change, and all three turn on a threshold rather than on a smooth scale:
| Threshold | What changes | Source |
|---|---|---|
| 9 litres water capacity | the acetone charge band | IS 7312:1993 cl 19.3.2 |
| 10 litres water capacity | minimum shell thickness, 2.5 mm below and 3.5 mm above | IS 7312:1993 cl 6.2.2 |
| Welded against seamless | whether fusible plugs are fitted, and the test pressure | IS 7312; GCR 2016 Rule 37(vii) |
Both common Indian sizes sit above both thresholds, so in practice a buyer meets the thicker shell and the higher acetone band either way.
The figure buyers miss: size sets the draw rate #
A larger cylinder is not only more gas. It is a higher safe withdrawal rate.
Continuous draw from a dissolved acetylene cylinder is limited to roughly one-seventh of its contents per hour. Exceed it and acetone leaves with the gas, which contaminates the work, starves the cylinder of solvent and, over enough cycles, makes it less resistant to a flashback.
So a bank is sized on the rate of burn, not the volume consumed in a month. Two cylinders on line at 7 kg each support a far higher torch load than four at 3.2 kg support in sequence. The arithmetic is on the one-seventh rule, and manifold and cascade sizing is on manifolds and bulk supply.
What to ask about a cylinder size #
Four questions, and the first one makes the rest comparable.
- What is the water capacity in litres? A rate per cubic metre only compares if the cylinders match. A nominal name is not an answer.
- What is the stamped tare, and the acetone charge? Both are permanent markings, and the tare is what the weighing is done against.
- Whose cylinder is it? Yours or the supplier's decides whether a cheap rate turns dear once cylinders sit idle on site between jobs.
- When is the next periodic test due? It is on the ring between the valve and the neck, and a cylinder past it must not be filled or transported.
A size in India is stated as water capacity in litres, never as cubic metres of gas. The two common sizes are about 17 litres, holding roughly 3.2 kg of gas, and 41 litres holding roughly 7 kg — against tares of 29 kg and 55 kg, so most of what is lifted is not acetylene. What KIGL supplies, and how supply works beyond the Guwahati delivery radius, is on dissolved acetylene.
Acetylene cylinder sizes — frequently asked questions
What size acetylene cylinders are available in India?
Two sizes cover almost all industrial use. The smaller is about 17 litres water capacity and holds roughly 3.2 kg of acetylene; the larger is 41 litres and holds about 7 kg. The 41 litre size is made both as a three-piece welded shell and as a seamless one, which changes the dimensions and the tare without changing the gas it holds.
Why is an acetylene cylinder sized in litres rather than cubic metres?
Because the litres describe the vessel and the cubic metres would describe the contents, and in a dissolved acetylene cylinder those are not proportional. The shell is filled with a porous mass soaked in acetone, and the gas is dissolved into that acetone. Water capacity is the one dimension that is fixed and measurable, so every standard and every filling rule is written against it.
How much gas is in a 41 litre acetylene cylinder?
About 7 kg, which is roughly 6.4 m³ of gas at 0.91 m³ per kg. But the figure that matters on the day is not the nominal one: the actual content is the gross weight minus the tare stamped on the shoulder. See [checking contents by weight](/guides/how-to-check-acetylene-cylinder-contents-by-weight).
Why is an empty acetylene cylinder so heavy?
Because it is not empty. A 17 litre cylinder has a tare of about 29 kg and a 41 litre one about 55 kg, and most of that is the monolithic porous mass and the acetone charge, both of which stay in the cylinder for its whole life. The acetone alone occupies around 43 % of the water capacity by volume.
Does the size change the pressure the cylinder works at?
No. Every dissolved acetylene cylinder is limited to 16 kgf/cm² settled at 15 °C under Rule 37(vi) of the Gas Cylinders Rules 2016, whatever its size. What changes with size is the shell thickness, which IS 7312:1993 cl 6.2.2 sets at 2.5 mm up to 10 litres and 3.5 mm above it.
Do all sizes carry fusible plugs?
Not necessarily. Welded DA cylinders in the Indian market are commonly supplied with two fusible plugs, while a seamless shell may be supplied without them and tested to a much higher hydrostatic pressure instead. The plug itself yields at 100 °C, +4/−2, under IS 13497:2017. See [fusible plugs](/guides/acetylene-cylinder-fusible-plugs-is-13497).
What should I ask a supplier about cylinder size?
Ask for the water capacity in litres, not a nominal name, because a rate per cubic metre only compares if the cylinders match. Then ask the stamped tare, the acetone charge, and whether the cylinder belongs to the user or to the supplier. The last one decides whether a cheap rate turns dear in holding charges.
Does cylinder size affect how fast I can draw gas?
Yes, and this is the figure most buyers miss. Continuous withdrawal is limited to about one-seventh of the cylinder's contents per hour, or acetone comes out with the gas. A larger cylinder therefore gives a higher safe draw rate, and a bank is sized on the rate rather than on monthly consumption. See [the one-seventh rule](/guides/acetylene-cylinder-withdrawal-rate-one-seventh-rule).
References
Bureau of Indian Standards.
- IS 7312:1993Dissolved acetylene cylinders (1993) [specification (cl 6.2.2, 19.2.4, 19.3.2)]
Government of India.
- G.S.R. 1081(E)Gas Cylinders Rules, 2016 (2016) Petroleum and Explosives Safety Organisation. [Rule 37 (dissolved acetylene)]
- Jai Maruti Gas Cylinders Ltd, published DA cylinder specifications (JMC-17D, JMC-41D, JMC-S-41D) https://www.jaimarutigascylindersltd.com/dissolved-acetylene-cylinders-480941.html
Miller, S. A.
- (1965)Acetylene: Its properties, manufacture and uses (Vol. 1) Ernest Benn. [)]
Enquiries
Request a quotation
State the gas or equipment, the quantity or capacity, and your location. KIGL will confirm the grade, the cylinder or plant size, and whether the location can be served from Noonmati, or through the agent network.