Acetylene compressor troubleshooting symptom by symptom
On a 3-stage acetylene compressor, pressure high in any stage means a valve on the next higher stage is leaking, and a safety valve lifting names the stage above it. Oil pressure below 0.5 kg/cm²g is the pump belt, the level, or suction near zero. Grey oil is water.
- The master rule
- Pressure high in a stage means a valve on the NEXT HIGHER stage is not working
- Pressure switch settings
- High 24 kg/cm²g
- Low oil pressure threshold
- Below 0.5 kg/cm²g is a fault
- Normal oil pressure
- 0.2 to 0.8 kg/cm² above suction
- Oil pump belt
- Cogged belt
On this page 8 sections
How to use this page #
Every symptom here comes from the compressor's own operating manual, in the order the manual puts the causes. Work down the list rather than across it: the causes are ranked, and the first one is the commonest.
Two things before any of it. The machine is never run without a working force-feed oil pump — bearings, rods and pistons running dry generate friction heat with no upper limit, and a hot internal surface in pressurised acetylene is a recognised ignition route. And keep a maintenance log, because a fault that recurs is a different problem from a fault that happens once, and only the log distinguishes the two.
The one rule that finds most valve faults #
Pressure too high in any of the three stages means a valve on the next higher stage is not functioning properly.
That is the manual's own sentence, and almost everything else follows from it.
| What appears | What it means | What to do |
|---|---|---|
| First-stage pressure high | Second-stage valves leaking | Remove the second-stage head; clean or replace the valve |
| Second-stage pressure high | Third-stage valves leaking | Remove the third-stage head; clean or replace |
| First-stage pressure low | First-stage valves leaking | Clean, then lap with fine grinding compound |
| Not pumping to capacity | First-stage valves | Clean; if capacity does not return, lap them |
After any valve work, read every stage again. A leaking valve moves the balance of the whole machine, so a single corrected reading proves nothing on its own.
Safety valves name the stage above them #
| Symptom | Cause | Action |
|---|---|---|
| First-stage safety valve lifts | Second-stage valves leaking | Remove the second-stage head |
| Second-stage safety valve lifts | Third-stage valves leaking | Remove the third-stage head |
| Third-stage safety valve discharges rapidly | The compressor outlet valve is shut | Open it — and check the high-pressure switch, which should have stopped the machine first. No valve may sit between the pressure switch connection and the compressor |
That last row is worth reading twice. A safety valve doing its job is a machine whose first protection already failed.
Oil pressure below 0.5 kg/cm²g #
In the manual's order:
- Oil pump belt broken. Loosen the sheave from the hub to fit the new belt. It is a cogged belt that drives by its teeth, so it is meant to be slack — not tensioned like a vee belt — and it must never be stretched over the pulley flange.
- Oil level too low. Check and top up.
- Compressor suction near zero. Restore suction before blaming the pump.
- Oil pump suction line clogged. Clean it.
- Pump defective. Repair or replace.
The normal running band is 0.2 to 0.8 kg/cm² above suction pressure, which is the figure on the hourly shift log.
Rules that matter
Grey oil, and the water behind it #
Grey oil is water, every time. The gas arrives from the generator saturated on purpose — wet acetylene is safer to compress than dry — so moisture condenses through the stages and works its way into the crankcase.
Drain the whole charge and refill. Never top up. Then find the source:
- Traps not drained on schedule The suction, first- and second-stage traps are drained hourly through the shift and all of them at shutdown.
- A trap drain valve leaking, usually dirt under the seat. With the compressor stopped and the acetylene vented, disconnect the trap drain pipe between the filter and the fore-cooler end, start the compressor, and watch the drain valves for leaks. Remove the leaking one, clean or replace it.
- A detergent oil has been used Drain it and refill with an approved non-detergent grade. A detergent oil holds water as a grey emulsion that carries no film; a non-detergent one lets it settle where it can be drained.
A level that rises by half an inch with no oil added is the same signal arriving earlier.
When the machine stops before charging pressure #
| Cause | What to do |
|---|---|
| Momentary power failure | Restart |
| Magnetic starter not holding | Reset the starter overloads |
| High-pressure switch set too low | Reset high at 24 kg/cm²g and low at 3 kg/cm²g. If the manifold gauges and the switch disagree, the switch has drifted |
| Suction fell enough for the low-pressure switch to stop it | The fault is upstream — see below |
Suction that keeps falling is someone else's problem, reported here. Reduce to 3 kg/cm²g, restart, and watch the suction gauge. If it drops back towards the stopping pressure, work backwards through the purifier, the low-pressure drier, the generator flash back arrestor and the generator tank until the restriction is found. The plant troubleshooting guide covers each of those stages in turn.
When it knocks #
A knock on this frame is a bush — the gudgeon pin bush, the connecting-rod bush or the crankpin bush — and not the main bearings. The parts schedule agrees: the crankpin cap, body and bush are separate serviceable items, while the crankshaft is supplied as an assembly complete with its bearings and is replaced rather than rebuilt.
Check in this order: the bushes, then piston ring end gap against 0.005–0.015 in with ring gap clearance nowhere exceeding 0.13 mm, then valve head torque at 25 ft·lb (3.5 kg·m), tightened to the lower limit rather than the upper. A crankcase leak is confirmed by pressurising to 5 psig or more and watching for bubbles; a machine that will not hold 2 psig through a shutdown has a leak to find.
The master rule is worth carrying away on its own: pressure high in a stage means a valve on the next higher stage is not working. The settings that bracket it are a high switch at 24 kg/cm²g, a low switch at 3 kg/cm²g, and anything below 0.5 kg/cm²g of oil pressure treated as a fault. The machine itself, its capacities and its spares tiers are on acetylene compressors.
Acetylene compressor troubleshooting — frequently asked questions
What does it mean when a stage pressure reads high?
A valve on the next higher stage is not working properly. First-stage pressure above its band points at the second stage's valves, and second-stage pressure points at the third. Remove that cylinder head, clean or replace the valve, then re-check the pressure in every stage rather than only the one that complained — a leaking valve shifts the whole balance.
A safety valve lifted. Which one tells me what?
The stage above it. A first-stage safety valve lifting means the second-stage valves are leaking; a second-stage one means the third stage. A third-stage safety valve discharging rapidly is different: it means the compressor outlet valve is shut, and the high-pressure switch should have stopped the machine before the safety valve ever lifted. Check the switch, and check that no valve sits between its connection and the compressor.
Why is my oil pressure low?
Below 0.5 kg/cm²g is a fault, and the causes come in order: a broken oil-pump belt, oil level too low, compressor suction near zero, a clogged pump suction line, or a defective pump. The belt is the first thing to look at and the easiest to refit wrongly.
How is the oil pump belt fitted?
Loosen the sheave from the hub and fit the belt slack. It is a cogged belt that drives by its teeth, not by tension, so it should not be tight like a vee belt. Never stretch it over the pulley flange — that damages the cogs and the belt fails early.
The oil has gone grey. What now?
Grey oil is water, and the whole charge is drained and replaced rather than topped up. Then find where the water came from: traps not drained on schedule, a leaking trap drain valve, or a detergent oil in use, which holds water as an emulsion instead of letting it settle out. A rise of half an inch in the oil level with no oil added is the same signal.
The compressor is not pumping to capacity. Where do I start?
First-stage valves. Clean them, and if capacity does not come back, lap them with a fine valve grinding compound. Capacity loss is a valve problem far more often than it is a wear problem.
It stops before reaching charging pressure. Why?
Four candidates: a momentary power failure, the magnetic starter not holding, the high-pressure switch set too low, or suction falling far enough for the low-pressure switch to stop the machine. Reset the high indicator at 24 kg/cm²g and the low at 3 kg/cm²g; if the manifold gauges disagree with the switch, the switch calibration has drifted.
Suction keeps falling. Is the compressor at fault?
Usually not. Reduce to 3 kg/cm²g, restart, and watch the suction gauge. If suction falls back towards the stopping pressure, the restriction is upstream: check the gauges at the purifier, the low-pressure drier, the generator flash back arrestor and the generator tank to find where flow is being throttled. The compressor is reporting someone else's problem.